To configure a connection to a Modbus device, navigate to Connectivity -> PLC -> Modbus in the navigation tree as depicted below:
The page provides an overview of the currently configured connections including its Name, its IP Address, its connection Status and its Enabled status.
Column Name | Information Details |
---|---|
Name | Connection name as defined at creation time |
IP Address | IP address or host name of device |
Status | Status of connection |
The connection status can be Connected if the connection to the device is established or Disconnected if there is no connection to the device |
|
The connection status is dynamically updated every 2 seconds. | |
Enabled | Configuration status of the connection |
Possible values are Enabled or Disabled . |
|
Note: | |
Clicking the current configuration status icon triggers a state toggle: Enabled -> Disabled respectively Disabled -> Enabled |
From the title bar of the connection overview table a new connection can be added and existing connections can either be edited or deleted.
Adding a new connection and editing an existing connection, both open an identical page. The only difference is, that for an existing connection the Connection Name property cannot be changed.
The configuration parameters are described below:
Parameter Name | Default Value | Description |
---|---|---|
Connection Name | <empty> | Connection name as it will show up in the connection overview page |
The connection name has to be unique and can only be assigned when adding a new connection. | ||
Note: | ||
The following characters are not supported in the Connection Name field: # ^ < > / $ | ||
Enabled | Enabled | Instructs dataFEED edgeConnector Modbus to either Enable (checked) or Disable (unchecked) the currently configured connection. |
Txt-File | An ASCII text file with the address-space definition to upload, see Modbus Item Syntax | |
Address | <empty> | Address of the target device. This is either an IP address or a hostname. |
Select Address Spaces | AllConnection | Destination aggregation address space used to store the address space corresponding to this connection |
AddressSpace | It is possible to create additional aggregation address spaces by filling in the desired address space name in the input field and clicking the Add button. All available address spaces are visible in a list and can be selected as destination address space for the OPC UA Client connection by checking the corresponding checkbox. | |
For more details about the OPC UA Server functionality and configuration please refer to the OPC UA Configuration page. |